HT 10 Ton Digital Cone penetrometer

This is the Vertek HT 10 Ton Cone Penetrometer
The digital electronic tension 10 ton cone penetrometer is designed to address the accuracy, sensitivity and durability problems inherent in other cone designs of the same or lower capacity. With a resolution of 3 pounds, this cone provides excellent data for softer materials and eliminates the need for other low capacity cones.
10 Ton Cone Penetrometer
![]() Call Carl now to discuss pricing and fast delivery. ![]() |
The unit consists of a dual element strain gauge transducer, with the cone electronics packaged directly behind the transducers. The cone channels are temperature compensated to provide stable readings during testing. The cone tip, sleeve (local friction element) and pore pressure element (filter) are easily and quickly changed when necessary by the operator.
The cone is available with our standard channels (tip, local friction, pore pressure, inclinometer, seismic, and temperature) and can be used in conjunction with our Vision or Resistivity modules.
Pore Pressure can be measured in either U1 or U2 position (on the face of the tip or just behind the tip) (U2 shown in the screenshot)
We manufacture this cone penetrometer in not only 10 ton cone, but also a 5 ton range for cpt direct push.
- Tip
- Local Friction
- Pore Pressure
- Temperature
- Inclination
- Seismic
- 10 Ton Cone Soil Moisture Resistivity Module (optional)
- 10 Ton Cone Video Module (optional)
Calibration data for tip, local friction and pore pressure channels is stored in CPU non-volatile memory. Vertek Digital Cone Penetrometers conform to all international standards.

| Max Tip Force | 5 Ton | 10 Ton | ||||
| Resolution | 1.1uV | 1.1uV | ||||
| Maximum Sensor Input | 3.5V | 3.5V | ||||
| Power Requirements | 12VDC | 12VDC | ||||
| Tip | ||||||
| area | 10cm2 | 10cm2 | ||||
| range (kn) | 45 | 100 | ||||
| range (lb) | 10,000 | 22,000 | ||||
| range (mpa) | 45 | 100 | ||||
| overload capacity | 150% | 150% | ||||
| accuracy | 0.2% | 0.2% | ||||
| Sleeve | ||||||
| area | 150cm2 | 150cm2 | ||||
| range (kn) | 20 | 20 | ||||
| range (lb) | 4,400 | 4,400 | ||||
| range (mpa) | 1.3 | 1.3 | ||||
| Pore Pressure Transducer | ||||||
| standard range (kpa) | 6,900 | 6,900 | ||||
| standard range (kpa) | 1,000 | 1,000 | ||||
| burst pressure | 200% | 200% | ||||
| accuracy | 0.5% | 0.5% | ||||
| Inclinator (Dual Axis) | ||||||
| range (degrees) | 15 | 15 | ||||
| resolution (degree) | 0.1 | 0.1 | ||||
| Seismic | ||||||
| standard tri-axial geophone true DC response capacity: +/- | 2g | 2g | ||||
| Seismic signal is gained downhole by 1,10,100, or,100 and digitized in the Datapack no extra wires or analog measurement required | ||||||
Optional CPT Modules for the HT Series 10 Ton Cones
Data for this HT Cone is acquired with our HT Series FCS Data Acquisition System, available here.
This HT Cone works with our HT Series Soil Moisture Resistivity Module, available here.
This HT Cone works with our HT Series Video Module, available here.
Need more module options?
If you are interested in a 10cm2 10 ton cone capable of working with more optional modules, click here to look over our VTK Series 10cm2 10 ton cones, probes, modules and digital acquisition system
Download the
HT 10 Ton Cone Penetrometer Datasheet, here.